Sensors & Probes
Fluorescent Fiber Optic Temperature Probe
A quartz-fiber probe that carries light to and from a fluorescent sensing tip for point-based temperature measurement.

Confirmed capabilities
Engineered for electrically demanding temperature points
Quartz optical fiber
Confirmed for this product family; final implementation follows the selected model datasheet.
Configurable fiber length and sensing arrangement
Confirmed for this product family; final implementation follows the selected model datasheet.
Direct contact temperature measurement
Confirmed for this product family; final implementation follows the selected model datasheet.
Technical data
Confirmed Specifications
Only values confirmed on the permitted INNO product pages are listed. Configuration-specific items remain explicitly qualified.
| Temperature range | −40 °C to +240 °C; customizable for higher temperature |
|---|---|
| Resolution | 0.1 °C |
| Measurement accuracy | ±1 °C; higher-accuracy configurations are available |
| Fiber length | 3–5 m standard; configurable |
| Optical fiber | Quartz optical fiber |
| High-voltage resistance | 100 kV |
Operating principle
The monitor launches light into the probe and derives temperature from fluorescence decay time at the tip. Because the measured variable is lifetime, the method is designed to reduce sensitivity to optical intensity changes.
Installation approach
Protect the optical route from excessive bending, crushing and sharp edges. Position the sensing tip at the thermal point of interest and validate compatibility with insulation and manufacturing processes.
Communication and system integration
The probe is optical and connects to a compatible measurement instrument; communication is provided by that instrument.
Use the probe with an INNO monitor or sensing module selected for the required channel count and interface.
Typical Applications
Oil-immersed transformer windings
Confirm probe location, routing and instrument configuration against the equipment design.
Dry-type transformer windings
Confirm probe location, routing and instrument configuration against the equipment design.
Laboratory high-voltage test assemblies
Confirm probe location, routing and instrument configuration against the equipment design.
Technical questions
Frequently Asked Questions
Does the probe require a battery?
No. The measurement point is passive and optical.
What length should be specified?
The correct length depends on the equipment geometry, routing and service access. Confirm the final value on the project datasheet.
Engineering consultation
Specify Fluorescent Fiber Optic Temperature Probe
Send the equipment type, measurement points, temperature envelope and integration needs. We will help identify the configuration that requires confirmation.